The use of vascular robotic systems for PCI


Monday, 17 Feb 2014 12:37
Ronald P Caputo
Ronald P Caputo

By Ronald P Caputo


The aim of a vascular robotic system is to help interventional cardiologists perform percutaneous coronary intervention (PCI) procedures with greater precision. The systems are designed to provide greater accuracy of lesion measurement, aid in better advancement of guidewires, and help ensure correct placement of stents—which, all together, can lead to less instances of additional stent placement per lesion. For example, robotic systems allow for sub-millimetre movements to place stents and balloons, and can advance or retract guide wires with movements as small as a millimetre.


The precision afforded by these capabilities is greater than what can be achieved manually or using only visual estimates. Potentially, these subtle movements could mean the difference between a successful cardiac catheterisation procedure and one that requires secondary stent placement or a second procedure at a later date due to restenosis. Greater precision in stent placement is certainly warranted—using traditional PCI methods, up to 47% of stents longitudinal geographic miss using traditional methods1. These procedure variations can have a big impact on the incidence of target vessel revascularisation.


With a robotic system, the interventional cardiologist performs the PCI procedure from a “cockpit” rather than being next to the patient. The cockpit contains displays to visualise the procedure, and provides controls for the physician to manipulate the movement of interventional devices such as the guidewire and balloon/stent catheters via the bedside-mounted robotic arm. In my experience, I have found that performing PCI procedures from the cockpit also reduces physical fatigue from standing and leaning over the patient during the procedure.


Additionally, the cockpit’s radiation shielding eliminates the need for physicians to wear the heavy and cumbersome lead aprons used in traditional PCI procedures to protect against radiation exposure. Furthermore, the location of the cockpit in the cath lab provides radiation protection because it is positioned several feet away from the patient and the fluoroscopy unit (but is close enough to enable verbal contact between the patient and staff). The PRECISE study (sponsored by Corindus Vascular Robotics), released in April of 2013, showed that radiation exposure for the physician was reduced by 95.3% from traditional manual procedures; for patients, a reduction in radiation is afforded by the robot by a shortened procedure length. Personally, I welcome the introduction of a technology that will allow us to remove the threat of radiation during every procedure.


I have found that patients are comfortable with the increasing amount of technology that is used in care delivery, and are open to the use of vascular robotic systems provided they are informed about how they are used as well as the benefits they will receive from it. Because of the benefits brought by robotic assistance, I envision that the use of vascular robotic systems will expand into other cardiac procedures (eg. chronic total coronary occlusion, peripheral vascular disease and structural heart conditions) due to the increased level of precision that is offered. However, the key to increased industry acceptance and expansion of use lies with the level of commitment from the full cardiac catheterisation team: a commitment must be made to learning a new skill, training effectively and consistently using the technology.


Ronald P Caputo, interventional cardiologist, St. Joseph’s Hospital Health Centre, Syracuse, USA


Reference

1. Costa, MA. Am J Cardiol 2008; 101: 1704–11




Add New Comment

Most popular


Vascular Dynamics’ MobiusHD system receives CE mark for the treatment of resistant hypertension
Wednesday, 06 Jan 2016
The MobiusHD minimally invasive system from Vascular Dynamics has been granted CE mark approval for the treatment of resistant hypertension. Vascular Dynamics’ MobiusHD system receives CE mark for the treatment of resistant hypertension

US Medicare to cover Boston Scientific Watchman left atrial appendage closure device
Tuesday, 09 Feb 2016
The US Centers for Medicare and Medicaid Services (CMS) are to cover percutaneous left atrial appendage closure (LAAC) therapy under specific criteria, as outlined in the agency’s final National C... US Medicare to cover Boston Scientific Watchman left atrial appendage closure device

Orsiro may provide benefit over Xience for STEMI patients
Thursday, 07 Jan 2016
A pre-specified substudy of BIOSCIENCE, published in EuroIntervention, has found that Orsiro is associated with a significantly lower rate of target lesion failure than is Xience in STEMI patients at ... Orsiro may provide benefit over Xience for STEMI patients

Features


Building the ideal heart team for transcatheter mitral valve interventions
Monday, 08 Feb 2016
In this commentary, Vinayak Bapat outlines transcatheter mitral valve interventions and reviews which specialists should comprise the optimal heart team for such procedures. Building the ideal heart team for transcatheter mitral valve interventions

Training is the key to wider adoption of the transradial approach for PCI in the USA
Monday, 25 Jan 2016
This commentary explores why the USA, despite the data supporting the transradial approach, has been more reluctant than other countries to adopt the approach. Training is the key to wider adoption of the transradial approach for PCI in the USA

Profiles


Corrado Tamburino
Tuesday, 20 Oct 2015
Corrado Tamburino (full professor of Cardiology, Ferrarotto & Policlinico Hospitals, University of C... Corrado Tamburino

Javier Escaned
Wednesday, 02 Sep 2015
Javier Escaned (head of Section, Interventional Cardiology Unit, Hospital Clinico San Carlos, M... Javier Escaned

Cardiac Rhythm News Vascular News Cardiovascular News Interventional News Spinal News NeuroNews
BIBA Medical BIBA MedTech Insights CX Symposium ilegx
Password Reminder

BIBA Medical, 526 Fulham Road, Fulham, London, SW6 5NR.
TEL: +44 (0)20 7736 8788 FAX: +44 (0)20 7736 8283 EMAIL: 
info@bibamedical.com
© BIBA Medical Ltd is a company registered in England and Wales with company number 2944429.
VAT registration number 730 6811 50.
Site Map | Terms and Conditions