The use of vascular robotic systems for PCI


Monday, 17 Feb 2014 12:37
Ronald P Caputo
Ronald P Caputo

By Ronald P Caputo


The aim of a vascular robotic system is to help interventional cardiologists perform percutaneous coronary intervention (PCI) procedures with greater precision. The systems are designed to provide greater accuracy of lesion measurement, aid in better advancement of guidewires, and help ensure correct placement of stents—which, all together, can lead to less instances of additional stent placement per lesion. For example, robotic systems allow for sub-millimetre movements to place stents and balloons, and can advance or retract guide wires with movements as small as a millimetre.


The precision afforded by these capabilities is greater than what can be achieved manually or using only visual estimates. Potentially, these subtle movements could mean the difference between a successful cardiac catheterisation procedure and one that requires secondary stent placement or a second procedure at a later date due to restenosis. Greater precision in stent placement is certainly warranted—using traditional PCI methods, up to 47% of stents longitudinal geographic miss using traditional methods1. These procedure variations can have a big impact on the incidence of target vessel revascularisation.


With a robotic system, the interventional cardiologist performs the PCI procedure from a “cockpit” rather than being next to the patient. The cockpit contains displays to visualise the procedure, and provides controls for the physician to manipulate the movement of interventional devices such as the guidewire and balloon/stent catheters via the bedside-mounted robotic arm. In my experience, I have found that performing PCI procedures from the cockpit also reduces physical fatigue from standing and leaning over the patient during the procedure.


Additionally, the cockpit’s radiation shielding eliminates the need for physicians to wear the heavy and cumbersome lead aprons used in traditional PCI procedures to protect against radiation exposure. Furthermore, the location of the cockpit in the cath lab provides radiation protection because it is positioned several feet away from the patient and the fluoroscopy unit (but is close enough to enable verbal contact between the patient and staff). The PRECISE study (sponsored by Corindus Vascular Robotics), released in April of 2013, showed that radiation exposure for the physician was reduced by 95.3% from traditional manual procedures; for patients, a reduction in radiation is afforded by the robot by a shortened procedure length. Personally, I welcome the introduction of a technology that will allow us to remove the threat of radiation during every procedure.


I have found that patients are comfortable with the increasing amount of technology that is used in care delivery, and are open to the use of vascular robotic systems provided they are informed about how they are used as well as the benefits they will receive from it. Because of the benefits brought by robotic assistance, I envision that the use of vascular robotic systems will expand into other cardiac procedures (eg. chronic total coronary occlusion, peripheral vascular disease and structural heart conditions) due to the increased level of precision that is offered. However, the key to increased industry acceptance and expansion of use lies with the level of commitment from the full cardiac catheterisation team: a commitment must be made to learning a new skill, training effectively and consistently using the technology.


Ronald P Caputo, interventional cardiologist, St. Joseph’s Hospital Health Centre, Syracuse, USA


Reference

1. Costa, MA. Am J Cardiol 2008; 101: 1704–11




Add New Comment

Most popular


No severe paravalvular leak with Acurate Neo TF
Monday, 29 Sep 2014
Data presented at PCR London Valves (28–30 September, London, UK) indicate that the Acurate Neo transfemoral TAVI system, which recently received the CE mark, is not associated with any incidences of ... No severe paravalvular leak with Acurate Neo TF

First-in-man percutaneous repair of tricuspid valve performed
Wednesday, 08 Oct 2014
Mitralign has reported on the successful use of its technology to perform a percutaneous repair on a patient with tricuspid regurgitation. The company also announced that Joachim Schofer and Rebecca H... First-in-man percutaneous repair of tricuspid valve performed

Three studies show benefits of Perceval sutureless valve
Wednesday, 22 Oct 2014
Three studies presented at the 2014 EACTS annual meeting showed positive data for Sorin’s sutureless Perceval aortic valve. Three studies show benefits of Perceval sutureless valve

Features


The data for thrombectomy are conflicting
Wednesday, 05 Nov 2014
Sanjit Jolly writes that data suggest that impaired microvascular perfusion after primary percutaneous coronary intervention (PCI) is strongly associated with subsequent mortality.1 Manual ... The data for thrombectomy are conflicting

The promise of chemical renal denervation
Friday, 05 Sep 2014
Tim A Fischell writes that chemical renal denervation using ethanol may have numerous advantages over energy-based “burning” technologies. The promise of chemical renal denervation

Profiles


Sunil Rao
Thursday, 23 Oct 2014
Sunil Rao speaks to Cardiovascular News about his career highlights, including his research into ... Sunil Rao

Azeem Latib
Wednesday, 24 Sep 2014
Azeem Latib (senior interventional cardiologist, San Raffaele Hospital and EMO-GVM Centro Cuore C... Azeem Latib

Cardiac Rhythm News Vascular News Cardiovascular News Interventional News Spinal News NeuroNews
BIBA Medical BIBA MedTech Insights CX Symposium ilegx
 
Password Reminder

BIBA Medical, 526 Fulham Road, Fulham, London, SW6 5NR.
TEL: +44 (0)20 7736 8788 FAX: +44 (0)20 7736 8283 EMAIL: 
info@bibamedical.com
© BIBA Medical Ltd is a company registered in England and Wales with company number 2944429.
VAT registration number 730 6811 50.
Site Map | Terms and Conditions