Fewer ischaemic lesions with proximal balloon occlusion during carotid stenting


Wednesday, 23 Nov 2011 11:17

Results from the PROFI study indicate that the use of a proximal balloon occlusion in carotid artery stenting led to fewer cerebral ischaemic lesions than with the use of a filter. Trial results were presented at the TCT symposium in San Francisco.


Previous randomised trials have revealed a higher rate of stroke following carotid artery stenting when compared to surgical removal of plaque from the carotid artery. One of the reasons for this may be that the use of filters in carotid artery stenting allows plaque particles to travel to the brain. PROFI is the first randomised trial comparing proximal balloon occlusion with filter protection in patients undergoing carotid artery stenting.


In the PROFI (Prevention of cerebral embolization by proximal balloon occlusion compared to filter protection during carotid artery stenting) trial, 62 patients undergoing carotid artery stenting with cerebral embolic protection for a ≥60 % symptomatic or ≥80% asymptomatic internal carotid artery stenosis were randomly assigned to proximal balloon occlusion or filter protection. The primary endpoint was the incidence of new cerebral ischaemic lesions as assessed by diffusion weighted magnetic resonance imaging (DW-MRI). Secondary endpoints were the number and volume of new ischaemic lesions and major adverse cardiovascular and cerebral events (MACCE).


The incidence rate of new cerebral ischaemic lesions was 87.1% in the filter group, and 45.2% in the balloon group. The mean number of new cerebral ischaemic lesions was 3.5 in the filter group and 1.0 in the balloon group. There were no significant differences in MACCE at 30 days between the two groups.


“In this single centre, randomised trial in patients undergoing carotid artery stenting, the incidence, number, and volume of new cerebral ischaemic lesions were significantly lower under proximal balloon protection than under filter protection,” said Joachim Schofer, professor of Medicine, at the Medical Care Center, Professor Mathey, Professor Schofer, Hamburg University Cardiovascular Center. “A larger randomised trial with clinical endpoints is needed to investigate whether this benefit translates into a reduced periprocedural stroke rate,” said Schofer. 




Add New Comment

Related Items


Most popular


First drug-eluting balloon approved in USA
Friday, 10 Oct 2014
The FDA has approved the Lutonix drug-eluting balloon for the management of peripheral artery disease. This is the first time that the agency has approved such a device for this indication in the USA. First drug-eluting balloon approved in USA

Thursday, 25 Sep 2014
Operators should be aware of radiation exposure to the head increasing with angulation of the C-arm and limit this manoeuvre, according to a study presented at the ESVS Annual Meeting. C-arm angulation increases radiation exposure to the head during complex EVAR

Bioresorbable scaffolds can produce comparable acute results to metal stents
Tuesday, 04 Nov 2014
Speaking at the Asian Society for Vascular Surgery meeting (5–7 September, Hong Kong, China), Andrew Holden commented that studies indicate that bioresorbable scaffolds can produce comparable acute ... Bioresorbable scaffolds can produce comparable acute results to metal stents

Features


A new classification system for acute type B aortic dissection predicting reverse aortic remodelling
Wednesday, 19 Nov 2014
In recent years, primary stent grafting for complicated type B aortic dissection has been applied with favourable results. Thoracic aortic endovascular repair can be offered with a relatively low ... A new classification system for acute type B aortic dissection predicting reverse aortic remodelling

Resolving differences between carotid stenosis management guidelines
Wednesday, 19 Nov 2014
Anne Abbott, Melbroune, Australia, writes that while some variability in guideline recommendations is due to different publication dates, much is due to bias in what evidence is considered and how it ... Resolving differences between carotid stenosis management guidelines

Profiles


Martin Björck
Wednesday, 01 Oct 2014
Martin Björck, Uppsala University Hospital, Sweden, holds the only professor-chair of vascular ... Martin Björck

Cliff Shearman
Thursday, 03 Jul 2014
A former president of the Vascular Society of Great Britain and Ireland, Cliff Shearman was ... Cliff Shearman

Cardiac Rhythm News Vascular News Cardiovascular News Interventional News Spinal News NeuroNews
BIBA Medical BIBA MedTech Insights CX Symposium ilegx
 
Password Reminder

BIBA Medical, 526 Fulham Road, Fulham, London, SW6 5NR.
TEL: +44 (0)20 7736 8788 FAX: +44 (0)20 7736 8283 EMAIL: 
info@bibamedical.com
© BIBA Medical Ltd is a company registered in England and Wales with company number 2944429.
VAT registration number 730 6811 50.
Site Map | Terms and Conditions